Buying Guide
Fire + Security Dual-Rated Doors for Hotels and Hospitals
26 August 2026

One opening, two certificates — how to specify doors that pass both the fire inspector and the security audit.
In hotels, hospitals and apartment buildings, many openings must satisfy two inspectors at once: the fire officer, who cares about minutes of integrity, and the security auditor, who cares about forced-entry resistance. A door that passes one and fails the other is a retrofit waiting to happen — the answer is a genuinely dual-rated doorset.
WONLY's fire-rated security door project page provides the RFQ inputs, evidence checks and hardware-coordination path for these openings.
For mixed-use schedules that also include non-fire-rated secure openings, use the commercial steel security door project page to separate security, egress, access-control and traffic requirements by door mark.
Two Tests, One Construction
Fire performance (EN 1634) and burglar resistance (EN 1627 / GB 17565) are separate test regimes with different protocols. A dual-rated door is one construction that has passed both — which is an engineering achievement, because fire design favours intumescent seals and sacrificial layers while security design favours mass, bolts and rigidity. Only the test certificates prove the combination works.
Where Dual Rating Is Effectively Mandatory
- Hotel perimeter, back-of-house and service entrances on escape routes
- Hospital ward entries, pharmacies and records rooms inside fire compartments
- Apartment entrance doors — fire-rated by code, security-rated by residents' expectations
- Server rooms, plant rooms and any secure room whose walls are fire compartment lines
Specification Pitfalls to Avoid
- Two certificates from two different constructions — both must cover the same tested doorset
- Security hardware swapped onto a fire door after certification — this voids the fire rating
- A rated leaf in an unrated frame — the doorset is the certified unit
- Missing the closer and intumescent seals from the order — they are part of the tested set
How WONLY Builds Dual-Rated Doors
WONLY's engineering and medical-grade series carry EN 1634 90-minute fire integrity compliant with Gulf, SE Asia and Central Asia codes, while applicable models add GB 17565 Class A — the highest China security grade — with 200,000+ cycle-tested hardware and certification to ISO 9001/14001, CE, UL and CMA. One doorset, both certificates, with documentation ready for tender.
FAQ
Does adding a smart lock void a fire rating? It can, unless the lock is part of the tested configuration — specify smart access from the manufacturer's certified options rather than retrofitting.
Who should confirm the required minutes? The project's fire strategy document — take EI class and minutes per opening from it, then layer the security grade on top.